SideShot® Models HSJ, HS1, HS2

The SideShot® Series is recommended for oil applications. We recommend the use of our HS-Series venters for oil burner inputs larger than the SideShot® Vent System capacities. For Sidewall venting residential/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the UC1 Universal Control and a diaphragm Fan Proving Switch safety interlock which will shut down heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 Universal Control features include; adjustable pre and post-purge settings, LED Status/diagnostic indicators, Fan Prover switch monitoring. Interlocks with any 24-120 VAC burner control circuit and also includes “dry” contact actuation option. Easily interlock multiple appliances with our MAC-Series multiple appliance controls.

Model Number

Vent Pipe Diameter

BTU/hr Input

Max Pipe Length (feet) at Stack Temp

Gas Fired 300˚F

Max Pipe Length (feet) at Stack Temp

Gas Fired 400˚F

Max Pipe Length (feet) at Stack Temp

Oil Fired 500˚F

CFM at 70˚F

(Inches W.C.)

0”

.50”

.75”

1.0”

1.4”

HSJ**

4”

50,000

100

100

100

110

85

67

10

75,000

100

100

100

100,000

100

100

125,000

35

23

HS1**

4”

150,000

100

60

35

158

115

95

12

200,000

87

57

27

250,000

40

12

300,000

4

6”

150,000

100

100

100

200,000

100

100

100

250,000

100

92

300,000

30

HS2**

6”

350,000

100

100

100

286

235

215

196

158

400,000

100

100

100

450,000

100

100

67

500,000

100

72

550,000

94

600,000

15

8”

350,000

100

100

100

400,000

100

100

100

450,000

100

100

100

500,000

100

100

550,000

100

600,000

67

Oil applications must use the SideShot® Vent Systems or HSJ, HS1, HS2 models which include UC1 Control with integral Pre and Post-Purge settings.

Explore Your Results Here